TMC-MRI LAYOUT


TENTATIVE LAYOUT AND SPECIFICATION OF A TMC CONDUCTOR FOR MRI (wire in channel)

The TMC conductor will be soldered into an U-shaped copper profile.

​​​​​​​


​​​​​​​​​​​​​​

image-10075922-MRI-LAYOUT-16790.png



Wire OD = 0.57 mm

Total cross-section = 0.2593 mm2

Ic = 500 A @ 6 T

n ≥ 40

Iop = 325 A (65% of 500 A) - Jop = 1’250 A/mm2

Filament OD = 56 micrometer

Number of filaments = 54

Matrix / TMC = 0.95

ss/Mo = 5

​​​​​​​